• Type Approval:
  • Back

Product Details

Details of Equipment:
image of product
Product Type: Ultrasonic Water Meter with C-cell Battery
Brand Name: Kamstrup
Model Number: flowIQ2101 (MULTICAL 21)
NCA Equipment No.: EX6-H5-GE2-X40
Product Name: Ultrasonic Water Meter with C-cell Battery
Intended Use: Water Meter
Additional Details for Radio Equipment:
Frequency Range: 868.70 – 869.20 MHz
RF Output Power Radiation: 12.97 dBm e.r.p.
RF Output Power Conducted:
RF Channel Spacing:
RF Output Impedance:
Type Of Modulation: 2-FSK
Bandwidth: 0.216 MHz
Software Version:
Antenna Type: Integrated
Antenna Gain: -1.2 dBi
Technical Variants:
Details of Certificate of Compliance:
Issuing Body: Kamstrup A/S
Issuing Date: 09/15/2017
Validity: lifetime
Standards:
EMC: OIML R 49-2
Radio: EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
Health And Safety: EN 62311
Manufacture's Information:
Name Of Manufacturer: Kamstrup A/S
Address Of Manufacturer: Industrivej 28, 8660 Skanderborg, Denmark